Temperature measurement in the flowing medium
Temperature measurement in the flowing medium
Blog Article
The article deals with a brief description of methods of temperature mule skinner knife measurements in a flowing water steam.Attention is paid to the measurement of pseudo static temperature by a single sealed thermocouple entering the flowing liquid through the flown-by wall.Then three types of probes for stagnation temperature measurement are shown, whose properties were tested using CFD calculations.The aim was to design a probe of stagnation parameters of described properties which can be used for measuring flow parameters in a real steam turbine.An important factor influencing echofix spring reverb the construction is not only the safe manipulation of the probe when inserting and removing it from the machine in operation, but also the possibility to traverse the probe along the blade length.